> For the complete documentation index, see [llms.txt](https://docs.vega365.com/llms.txt). Markdown versions of documentation pages are available by appending `.md` to page URLs; this page is available as [Markdown](https://docs.vega365.com/redundancy-management-framework/user-manual/high-availability-alarms/alarm-configuration/add-an-rmf-alarm/maps-support.md).

# Maps Support

Associate a Map with an RMF Alarm

## Overview

This instruction is directed toward system administrators, security operators, and IT personnel who need to connect maps with RMF alarms in Milestone XProtect. Associating maps helps represent the location of the camera that triggered the alarm.

<figure><img src="https://73860689-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FK95oxUATgzuZZ2VhRoDw%2Fuploads%2FOr6I7wJaeqLHqR8M4mxo%2Fimage.png?alt=media&amp;token=c779015f-6202-4934-9201-8ce790b4997f" alt=""><figcaption><p>RMF Alarm with map</p></figcaption></figure>

## Use this Guide if You Want To

* Associate a map with an **existing RMF alarm**
* Associate a map with a **new RMF alarm**

> **Note:** Map association is **not supported** in [Federated](https://docs.vega365.com/redundancy-management-framework/user-manual/architecture-options/federated.md), and [Independent](https://docs.vega365.com/redundancy-management-framework/user-manual/architecture-options/independent.md) Redundancy types. At this time, it is only supported for a [Single Site](https://docs.vega365.com/redundancy-management-framework/user-manual/architecture-options/single-site.md) architecture.

## A Workaround

Milestone’s SDK currently does not support directly linking maps to alarms. Consequently, when alarms are triggered via SDK-based integrations (such as RMF), there is no built-in method to include map data.

Since RMF uses SDK-based methods to ensure high availability of alarms, users seeking map visualization must apply a workaround. The following steps provide a practical solution to associate maps with RMF alarms.

To enable map association, we use a **dummy native alarm** that is pre-configured with the desired map. When an RMF alarm is triggered, this dummy alarm is also activated, automatically launching the associated map in the Smart Client.

## Steps to Implement the Workaround

The steps below must be repeated for each RMF alarm that requires a map to be associated with it.

### A. Create an Analytics Event

1. In the Management Client, navigate to **Rules and Events,** and then select **Analytics Events**.
2. Click **Add New**.
3. Provide a **unique name** for the event (avoid duplicates).
4. Click **Save**.<br>

   <figure><img src="https://73860689-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FK95oxUATgzuZZ2VhRoDw%2Fuploads%2Fl6t3ZjR63lfRcCuedTSl%2Fimage.png?alt=media&amp;token=e68bb80a-55e9-4cad-ab8f-93485963d9ba" alt="" width="563"><figcaption><p>Analytics Events</p></figcaption></figure>

### B. Configure a Dummy Native Alarm

1. Navigate to **Alarms** > **Alarm Definitions.**
2. Click **Add New**.
3. Provide a name for the alarm.
4. Under the **Trigger** section:
   1. Select **Analytics Event** as the triggering event.
   2. Choose the event created in Step 1.
5. Select any source camera (the camera selected is irrelevant, as this is a dummy alarm).
6. Choose the **map** that should be associated with this dummy alarm.
7. Click **Save**.<br>

   <figure><img src="https://73860689-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FK95oxUATgzuZZ2VhRoDw%2Fuploads%2FGAiGqJjqrEzAQcSvEBtv%2Fimage.png?alt=media&amp;token=3fd8fd0b-a64a-46de-a719-5938951c9f14" alt=""><figcaption><p>Native Alarm</p></figcaption></figure>

### C. Link Dummy Alarm to RMF Alarm

#### Edit RMF Alarms already configured

1. Navigate to **Site Navigation** > **MIP Plugins**.
2. Expand **RMF** and select **Alarms**.
3. Choose the RMF alarm that you want to link with a map.
4. From the available options, select **Associate Map**.

<figure><img src="https://73860689-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FK95oxUATgzuZZ2VhRoDw%2Fuploads%2FRLQ3Swk6vJloKnOSdrUh%2Fimage.png?alt=media&amp;token=a023e901-ec24-42c0-8c53-9f42a708de2e" alt=""><figcaption><p>Native Alarm to RMF Alarm</p></figcaption></figure>

5. Choose the **dummy native alarm** configured in [#b.-configure-a-dummy-native-alarm](#b.-configure-a-dummy-native-alarm "mention")

<figure><img src="https://73860689-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FK95oxUATgzuZZ2VhRoDw%2Fuploads%2Fi09fxvWUxislnIya0clC%2Fimage.png?alt=media&amp;token=24d50538-52d6-41a4-b2ab-9aa065e62cc0" alt=""><figcaption><p>Native Alarm to RMF Alarm</p></figcaption></figure>

6. Click **Save**.

#### For a new Alarm

See: [Add an RMF Alarm](https://docs.vega365.com/redundancy-management-framework/user-manual/high-availability-alarms/alarm-configuration/add-an-rmf-alarm.md)

### D. View Alarm with Associated Map in the Smart Client

1. Open the **Smart Client** application.
2. Go to the **Alarm Manager** tab.
3. Select the RMF alarm from the list.
4. If the alarm is mapped, the configured **map** and associated **video** will open automatically.<br>

   <figure><img src="https://73860689-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FK95oxUATgzuZZ2VhRoDw%2Fuploads%2FOr6I7wJaeqLHqR8M4mxo%2Fimage.png?alt=media&amp;token=c779015f-6202-4934-9201-8ce790b4997f" alt=""><figcaption><p>Alarm</p></figcaption></figure>

## Conclusion

This guide provides a reliable workaround for linking maps with RMF alarms in Milestone XProtect. While direct map association is not supported due to SDK limitations, this method ensures that alarms triggered via RMF can still visually represent the event’s location, thereby improving situational awareness and operational efficiency.