> For the complete documentation index, see [llms.txt](https://docs.vega365.com/llms.txt). Markdown versions of documentation pages are available by appending `.md` to page URLs; this page is available as [Markdown](https://docs.vega365.com/xport/user-manual/volume-migration/step-by-step-user-guide/check-for-duplicates.md).

# Check for Duplicates

Before migration, check whether the **destination Recorder** already contains any devices that exist on the **source volume** being migrated. XProtect permits multiple Recorders to record the same video streams from the same cameras, so duplicates are possible.

<figure><img src="https://771655570-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2Fxj7X0c61rEOwTqSjg2jo%2Fuploads%2FyQlZfZXghENDh51QK1By%2Fcheckforduplicates.png?alt=media&amp;token=8c49b043-f89b-4655-ae71-30240c614c2f" alt=""><figcaption></figcaption></figure>

If duplicates are detected, follow these steps to resolve them **before proceeding with migration**:

1. **Review the Duplicates List** in XPort.
2. **Close XPort.**
3. **Remove the duplicate devices** — either from the source Recorder or from the destination Recorder, as appropriate.
4. **Restart XPort and begin the migration process again from the start.**

Restarting ensures that XPort revalidates the XProtect configuration after duplicates have been resolved, preserving system integrity before any volume is detached.